Software Installation
Set Up LAN
2-16 Strata CIX PC Attendant Console Installation 06/09
Set Up LAN
Enter data for Program 803 first, then enter data for Program 801 second.
1. Select System > IO Device > I/O Logical Tab (Program 803) and enter the following FBs to
establish one of the system ports for use as a LAN port:
p FB00 – CSTA logical device ports are 200~208. Scroll down and select “200 CTI#0” or the
next unused port.
p FB01 – Choose LAN device connection. Assign a device port number. When
programming from a telephone, press Spkr to access this parameter.
Then enter a device port number.
2. Perform a Power Cycle or Level 2 Reset to reset the CIX system.
3. Select the LAN Tab (Program 801) and the following FBs to assign the properties of each LAN
port:
CSTA Link Setup
Program 803 Advanced Configuration > System > I/O Device > IO Logical Device
FB Description Setting
00 Logical Device Number
200 CTI#0 or next
available
01 Device Connection LAN
02 Port Index No. 1 or next available
Program 801 Advanced Configuration > System > I/O Device > LAN Device
00
LAN Port Index No. - Choose the device port number to be
assigned. Use port assigned in above step (Program 803, FB02).
1 or per assigned
in Prog 803
01 Protocol TCP
02 Application Type Server
03 Data Flow Asynchronous
04
Server Port No. - Assign the port to be a server that is linked to the
client (1100~1107 recommended). When you complete all Strata
CIX programming, be sure to enter this same port number in
“Modify TSP Configuration” on page 18.
1100
05 – 08 Leave at Default values