Software A3TY07X
Page 26
November, 2019
4.0 Utility Functions
4.1 EOI Access
This screen allows the user to set and change the password and define the functionality of the keypad.
The password when shipped from the factory is ‘0’. Entering the password will allow the user to change
the password to any number from 0 to 65535. The keypad only has one password. Once the password
is changed, only the new password will function.
The functionality of the keypad STOP button can also be defined from this screen. Programming a ‘1’ to
Stop Mode Flag will allow the keypad STOP button to stop the motor when the drive is running in remote
mode. Programming a ‘0’ to this flag will disable the STOP button when the drive is in remote mode. Be
aware that this function only works if the remote start/stop is done with momentary start and stop signals
(three wire control). It will not function if the drive is controlled via a single maintained contact.
The functionality of the keypad, as a whole, can also be set in this screen. This is accomplished with the
EOI Enable Flag. Programming this flag to ‘0’ will disable all functions except monitoring. Programming it
to ‘1’ will allow monitoring and operation of the drive. Programming it to ‘2’ will allow monitoring, operation,
and changing of parameters. To change the value stored in this flag, you must enter the password first.
4.2 Clock Set
This screen allows the time and date to be set. The EOI contains a real time clock with a replaceable
battery. It writes the time to the drives main control board when the drive control power is first energized.
The drive time and the EOI time are both displayed in this screen. The EOI date and time can be
changed via the UP and DOWN keys and the ENTER button. Once the EOI date and time are set, the
drive date and time can be synchronized to the EOI by holding down the ENTER key.
4.3 Contrast
This screen allows the user to adjust the LCD contrast. The contrast will change as the number is
changed, but to keep the new setting, the ENTER key or the encoder must be pressed to save the value.
If ESC is pressed, the setting will return to the old value.
4.4 Version
This screen allows the user to view the software version of both the EOI and the Drive.