E6582051
- 38 -
6.5.2. fa06 (Communication command1) (VF-AS3)
bit
Function
0
1
Note
0
Preset speed switching
1
0000: Preset speed operation
OFF(*1)
0001-1111: Setting of preset speed
operation frequencies (1-15)
Preset speed operation is
disabled or preset speed
operation frequencies (1-15) are
set by specifying bits for preset
speed operation frequencies 1-4.
1
Preset speed switching
2
2
Preset speed switching
3
3
Preset speed switching
4
4 V/f switching 1 (*2) V/f 1 V/f 2
V/f 1:
pt
= setting value,
vl, vlv, vb, thra
V/f 2:
pt
= 0,
f170
,
f171
,
f172
,
f182
5
PID control
Normal operation
PID off
-
6
Acc/Dec switching 1
(*3)
AD mode 1 AD mode 2
AD mode 1:
acc
,
dec
AD mode 2:
f500
,
f501
7 DC braking OFF
Forced DC
braking
-
8
Jog run
OFF
Jog run
-
9
Forward/Reverse
Forward run
Reverse run
-
10
Run/stop
Stop
Run
-
11
Coast stop command
Standby
Cost stop
-
12
Emergency stop
OFF
Emergency stop
Always enable, "E" trip
13
Fault reset
OFF
Reset
No data is returned from the drive
14 Frequency priority OFF Enabled
Enabled regardless of the setting
of
fmod
15 Command priority OFF Enabled
Enabled regardless of the setting
of
cmod
(*1): When 12(
sr0
) is set to
fmod
, preset speed operation frequency 0 is selected.
(*2): The V/f switching ORs with Bit 10 of
fa23
.
(*3): The Acc/Dec switching ORs with Bit 8 of
fa23

Table of Contents

Other manuals for Toshiba Tosvert VF-S15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Tosvert VF-S15 and is the answer not in the manual?

Toshiba Tosvert VF-S15 Specifications

General IconGeneral
CategoryInverter
Control MethodV/f control, Sensorless vector control
Cooling MethodForced air cooling
ModelTosvert VF-S15
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Communication OptionsModbus RTU
Overload Capacity150% for 1 minute
Braking UnitBuilt-in braking transistor
Output Voltage3-Phase, same as input voltage
Operating Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20 to 65°C (-4 to 149°F)
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC
WeightVaries depending on model (e.g., 0.8 kg to 16 kg)