6F8C0878 77
7.2 Transmission Line Diagnosis Information
7
7.2.2 Transmission diagnosis information reference method
Transmission line diagnosis information covers Line A only if the transmission line is of a 
single configuration; or both Lines A and B if it is of a dual configuration.
Transmission line diagnosis information address
Base addresses of individual slots and addresses of module slots for socket 0 
information
Word offset
Line A information 130912 - 130927
Line B information 130928 - 130943
Base Address Top of Line A Information
Symbol name on 
Engineering Tool
Slot 0 0 %MW13.130912 EN_NODEMAPA_0
Slot 1 524288 %MW13.655200 EN_NODEMAPA_1
Slot 2 1048576 %MW13.1179488 EN_NODEMAPA_2
Slot 3 1572864 %MW13.1703776 EN_NODEMAPA_3
Slot 4 2097152 %MW13.2228064 EN_NODEMAPA_4
Slot 5 2621440 %MW13.2752352 EN_NODEMAPA_5
Slot 6 3145728 %MW13.3276640 EN_NODEMAPA_6
Slot 7 3670016 %MW13.3800928 EN_NODEMAPA_7