EasyManua.ls Logo

Tosot TUHD18ND3F1O - 7.2 Additional Special Functions

Tosot TUHD18ND3F1O
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOSOT DC INVERTER U-MATCH AIR
34
For example, E1 means high pressure protection during operation.
Figure 2-6-1
7 CENTRALIZED CONTROLLER
7.1 Smart Zone Controller
7.1.1 Function
The smart zone controller can directly control up to 16 sets of indoor units in a control network and is
available to check the running status of any unit through the LCD, including running mode, timer, fan
speed, centralized control and shielding setting etc.
7.1.2 Outline Drawing of Press Buttons
Figure 2-7-1

Table of Contents