TWP Weighing Indicator Service Manual
- 18 -
6. RS-232 OUTPUT
TWP series scales can take out data through RS 232 output.
Specifications:
RS-232 output of weighing data
Code : ASCII
Data bits : 8 data bits
Parity : No Parity
Baud rate : 600bps to 9600bps selectable
Connecter:
Pin 2: Input
Pin 3: Out put
Pin 5: Signal Ground
Continuously output protocol
Weighing mode.
Con1:
-14-
-/
k
g
CR
LF
HEADER1 HEADER2 WEIGHT DATA
HEADER1: ST=STABLE US=UNSTABLE
HEADER2: NT=NET GS=GROSS
WEIGHT UNIT
TERMINATOR