EasyManua.ls Logo

Toto EcoPower - User Manual

Toto EcoPower
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Warranty Registration and Inquiry
For product warranty registration, TOTO U.S.A. Inc. recommends online warranty registration. Please visit our web site
http://www.totousa.com.If you have questions regarding warranty policy or coverage, please contact TOTO U.S.A. Inc.,
Customer Service Department, 1155 Southern Road, Morrow, GA 30260 (888) 295-8134 or (678) 466-1300 when calling
from outside of U.S.A.
Installation and Owner’s Manual
Manual de Instrucciones y del Propietario
Manuel d’Installation et d’Utilisation
Manual de Instalação e do Proprietário
EcoPower Flush Valve
Fluxómetro EcoPower
Valve de Chasse EcoPower
Fluxômetro Self Power

Table of Contents

Other manuals for Toto EcoPower

Questions and Answers

  • W
    wsinghJul 27, 2025
    Why is no water coming from the Toto EcoPower Control Unit flush valve?
    • J
      Janet HuangJul 27, 2025
      If no water comes from the flush valve, several issues might be at fault: * The main valve in the water supply line or the control stop might be shut off. If so, open the main valve or the control stop. * The connector might not be connected; ensure the wire is connected. * The surface of the glass in front of the infrared sensor might be dirty; clean the glass surface. * There might be a reflective surface in front of the sensor; remove it. * The small holes in the solenoid diaphragm might be clogged; clean the small hole in the diaphragm and filter. * The hydropower generator might be clogged; service the hydropower generator. * If the glass is broken, or the infrared sensor or the solenoid is out of order, contact your distributor for a replacement.
  • J
    Jeffrey GregoryAug 2, 2025
    What to do if water does not stop flowing in Toto EcoPower?
    • K
      Kathy ChaseAug 2, 2025
      If the water doesn't stop flowing, check these potential causes: * The small hole in the piston is clogged (not for TEU*UA(R)(X)). Clean the small hole in the piston. * The sealing area of the piston is dirty (not for TEU*UA(R)(X)). Clean the sealing area of the piston. * The sealing area of the solenoid diaphragm is dirty. Clean the sealing area of the diaphragm and filter. * The Piston U-packing might be damaged (not for TEU*UA(R)(X)). Inspect and replace it if necessary.
  • A
    Amanda NortonAug 9, 2025
    How to adjust the flow rate on a Toto EcoPower Control Unit if it's too high?
    • T
      Tammy ParkerAug 9, 2025
      If the flow rate is too high, the control stop might not be adjusted properly. Adjust the control stop accordingly.
  • D
    dianehurleyAug 15, 2025
    How to fix low flow rate on Toto Control Unit?
    • G
      garrett08Aug 15, 2025
      If the flow rate is too low, it could be due to these reasons: * The water supply pressure is too low (below the rated minimum pressure). Consult with a plumbing contractor. * The control stop is not open enough. Adjust the control stop properly.
  • K
    Kevin RichardsonAug 20, 2025
    How to increase the discharge quantity of a Toto EcoPower Control Unit?
    • C
      cherylfloresAug 20, 2025
      If the discharge quantity is too small, the screw of the control stop or the screw of the piston valve are not adjusted properly. Adjust the discharge quantity by the screw of the control stop and the screw of the piston valve.

Summary

Included Parts

Common Tools Needed

Features

Specifications

Technical Information

About TOTOs Hydropowered Generator

Explains how the turbine generates power for the flush valve operation.

About Fuzzy Logic Control

Details how the valve adjusts water discharge based on usage frequency and duration.

Warnings

Before Installation

Toilet Flush Valve Installation Notes

Specific considerations for installing the toilet flush valve.

Urinal Flush Valve Installation Notes

Specific considerations for installing the urinal flush valve.

Reclaimed Water Flush Valve Installation Notes

Specific considerations for installing reclaimed water flush valves.

Installation Procedure - Large Cover

Installation Procedure - Small Cover

Other Base Frame Installation Options

Alternative methods for securing the base frame for small cover installations.

Test Run

Note to the Installer

Using the Flush Valve

Infrared Sensor Operation

Explains how the infrared sensor detects users for automatic flushing.

Flushing Mechanism

Details the timing and conditions for automatic flushing after user departure.

Manual Flushing Button

Instructions for using the manual flush button for maintenance or emergencies.

Periodic Trap Seal Flushing

System automatically flushes every 12/24 hours to maintain trap seal.

Periodic Maintenance

Care & Cleaning

Troubleshooting

Disassembly

Cleaning Piston Assembly

Cleaning Diaphragm and Filter

Checking Solenoid

Battery Replacement

Adjustment of the Flow Rate

The Detection Range

Detection Range Precautions

Advises on correct placement to avoid interference and ensure proper sensor detection.

Warranty

Rough-In Dimensions

Reclaimed Water Specifications

Toto EcoPower Specifications

General IconGeneral
BrandToto
ModelEcoPower
CategoryControl Unit
LanguageEnglish