5. Troubleshooting guide Swing gate control unit ST 61A
Error possible reason solution
no reaction after emitting a command
mains voltage missing
or fuse F1 defective
control of mains voltage as well as of
fuse F1
Display: error stop button check if stop button is properly con-
nected or bridged
control relays switch but motor does
not run
connection between motor and control
defective
check supply lines
gate opens but does not close
photocell interrupted check positioning and functions of
photocells
AR system actuated check force and sensor adjustment
safety sensing edge 1 or 2 actuated
adjustment of safety sensing edges
wrong
remove obstacle or function control via
status display
no reaction of radio receiver
radio receiver plugged into wrong
connector
check proper installation
see „connection of radio receiver“
no / wrong connected antenna check antenna connection
radio transmitter not programmed program handheld transmitter
error message „no learned way“
sensors/motors not correctly
connected or condenser not connected
check correct connection

Related product manuals