L2 Managed Switch
Installation
this instant current is strong enough to damage electronic devices, more effective
lightning protection measures should be taken.
Ensure the rack and device are well earthed.
Make sure the power socket has a good contact with the ground.
Keep a reasonable cabling system and avoid induced lightning.
Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note:
For detailed lightning protection measures, please refer to Chapter 3
Lightning Protection.
Installation Site
When installing the device on a rack or a flat workbench, please note the following
items:
The rack or workbench is flat and stable, and sturdy enough to support the weight
of 5.5kg at least.
The rack or workbench has a good ventilation system. The equipment room is well
ventilated.
The rack is well grounded. Keep the power socket less than 1.5 meters away from
the device.
2.3 Installation Tools
Phillips screwdriver
ESD-preventive wrist wrap
Cables
Note:
These tools are not provided with our product. If needed, please purchase
them.
2.4 Product Installation
Desktop Installation
To install the device on the desktop, please follow the steps below:
1. Set the device on a flat surface strong enough to support the entire weight of the
device with all fittings.
2. Remove the adhesive backing papers from the rubber feet.

Other manuals for TP-Link JetStream L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link JetStream L2 and is the answer not in the manual?

TP-Link JetStream L2 Specifications

General IconGeneral
BrandTP-Link
ModelJetStream L2
CategorySwitch
LanguageEnglish

Related product manuals