Printed in the Federal Republic of Germany TR-Electronic GmbH 2005, All Rights Reserved
07/30/2020 TR - ECE - BA - DGB - 0039 - 14 Page 107 of 107
9 Causes of faults and remedies
Error messages and resetting procedure see chapter 5.4.6, page 83.
Fault Cause Remedy
Position skips of the measuring
system
The special bits
"Encoder error",
"Dynamic error"
are set, see also
chap. 5.4.6, page 83
Strong vibrations
Vibrations, impacts
and shocks, e.g. on presses, are
dampened with "shock modules". If the error recurs
despite these measures, the measuring system must be
replaced.
Electrical faults
EMC
Perhaps isolated flanges and couplings made of plastic
help against electrical faults, as well as cables with twisted
pair wires for Clock±, Data±
section, cable length, shielding etc. see chapter 4
"Installation / Preparation for commissioning", page 66.
- Extreme axial and radial load
on the shaft
- Satellite scanning error
Couplings prevent mechanical stress on the shaft. If the
error still occurs despite these measures, the measuring
system must be replaced.
Memory error
If the error cannot be reset, the measuring system must be
replaced.