Hygiene Equipment
Designed for People
8
Installation instructions
Electrical
The bathtub is designed for 100-120V – 50/60Hz, 10A or 220/240V – 50/60Hz, 10A.
The control box for the lifting actuator is specified for 110-230VAC, +/-10%.
Voltage outside these norms will damage the linear actuator and control box.
The bathtub must be connected to the mains via a cord that is connected to a GFCI, Ground Fault Circuit
Interrupter, including an easily accessible switch near the bathtub (Not supplied by TR Equipment).
Polarity and grounding must be correct. Improper connection may result in injury.
The bathtub may only be used after it has been successfully and correctly installed.
All electric conduit, fitting and wiring to bath supplied must be installed by a certified
electrician in accordance with national/local regulations. Main switch, main fuse and Ground
Fault Circuit Interrupter are NOT included at delivery and must be supplied by others.