17 Series Mini-Split
install a drain pipe and connector (shown below).
A
t least 1 1/4 inch (31.8mm) clearance
Condensate Management of the Outdoor Unit
1. The outdoor unit(s) should be located where condensate poses no hazard or safety risk. Each
unit is supplied with a drain pipe connector.
2. Before installing the drain pipe tting, appropriately plug all other base pan holes not used.
3. Install the drain pipe tting into the appropriate hole located at the base of the unit and then
connect the drain pipe to it.
4.
4.
Place the outdoor unit on the support base
Place the outdoor unit on the support base
5.
5.
Secure the foot holes of the outdoor unit with bolts (shown below).
Secure the foot holes of the outdoor unit with bolts (shown below).