46
WSHP-SVX014J-EN
Electrical Data
Table 31. Electrical data - 0.75 to 6 tons, EX*009-070
Model No. Unit Volts
Total Unit
FLA
Comp RLA Comp LRA
Blower Motor
FLA
Blower Motor
HP
Minimum
Circuit
Ampacity
Maximum
Overcurrent
Protective
Device
EXV/H009 208-230/60/1 4.2 3.6 27.0 0.6 1/3 6/6 15/15
EXV/H009 265/60/1 3.5 3.0 22.0 0.5 1/3 5 15
EXV/H012 208-230/60/1 6.6 5.7 27.0 0.9 1/3 8/8 15/15
EXV/H012 265/60/1 5.3 4.5 32.0 0.8 1/3 7 15
EXV/H015 208-230/60/1 8.1 7.3 36.0 0.8 1/3 10/10 15/15
EXV/H015 265/60/1 5.5 4.8 30.0 0.7 1/3 7 15
EXV/H018 208-230/60/1 9.8 8.5 38.0 1.3 1/2 12/12 20/20
EXV/H018 265/60/1 7.9 6.8 35.0 1.1 1/2 10 15
EXV/H024 208-230/60/1 15.2 13.5 58.3 1.7 1/2 19/19 30/30
EXV/H024 265/60/1 10.5 9.0 54.0 1.5 1/2 13 20
EXV/H024 208-230/60/3 8.8 7.1 55.4 1.7 1/2 11/11 15/15
EXV/H024 460/60/3 4.4 3.5 28.0 0.9 1/2 6 15
EXV/H030 208-230/60/1 15.6 14.1 73.0 1.5 3/4 20/20 30/30
EXV/H030 265/60/1 12.5 11.2 60.0 1.3 3/4 16 25
EXV/H030 208-230/60/3 10.4 8.9 58.0 1.5 3/4 13/13 20/20
EXV/H030 460/60/3 5.0 4.2 28.0 0.8 3/4 7 15
EXV/H036 208-230/60/1 18.0 16.0 77.0 2.0 3/4 23/23 35/35
EXV/H036 265/60/1 13.9 12.2 72.0 1.7 3/4 17 25
EXV/H036 208-230/60/3 12.0 10.0 71.0 2.0 3/4 15/15 20/20
EXV/H036 460/60/3 5.7 4.7 38.0 1.0 1 7 15
EXV/H042 208-230/60/1 19.9 16.7 79.0 3.2 3/4 25/25 40/40
EXV/H042 208-230/60/3 13.6 10.4 73.0 3.2 3/4 17/17 25/25
EXV/H042 460/60/3 7.4 5.8 38.0 1.6 1 9 15
EXV/H048 208-230/60/1 20.5 17.9 112.0 2.6 1 25/25 40/40
EXV/H048 208-230/60/3 16.1 13.5 88.0 2.6 1 20/20 30/30
EXV/H048 460/60/3 7.3 6.0 44.0 1.3 1 9 15
EXV/H060 208-230/60/1 25.2 21.4 135.0 3.8 1 31/31 50/50
EXV/H060 208-230/60/3 18.3 14.5 98.0 3.8 1 22/22 35/35
EXV/H060 460/60/3 8.2 6.3 55.0 1.9 1 10 15
EXV/H070 208-230/60/1 31.4 26.4 134.0 5.0 1 39/39 60/60
EXV/H070 208-230/60/3 21.0 16.0 110.0 5.0 1 26/26 40/40
EXV/H070 460/60/3 10.3 7.8 52.0 2.5 1 13 20