Electrical Connections
Make wiring connections to the unit as indicated on enclosed wiring diagram. As with all gas appliances using electrical power, this furnace shall
be connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate "circuit protection device"
electric circuit. The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National
Electrical Code, ANSI/NFPA 70 or CSA C22.1 Electrical Code, if an external electrical source is utilized. The integrated furnace control is
polarity sensitive. The hot leg of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram.
Refer to the Wiring Diagram section in this document and unit wiring diagram attached to furnace.
WWAARRNNIINNGG
FFIIRREE HHAAZZAARRDD!!
FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinn pprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorr ddeeaatthh..
TThhiiss WWaarrnniinngg aapppplliieess ttoo iinnssttaallllaattiioonnss wwiitthh aa ffllaammmmaabbllee rreeffrriiggeerraattiioonn ssyysstteemm.. TThhee ffuurrnnaaccee mmuusstt bbee ppoowweerreedd
eexxcceepptt ffoorr sseerrvviiccee.. TThhee ffuurrnnaaccee sshhaallll bbee iinnssttaalllleedd aanndd ccoonnnneecctteedd aaccccoorrddiinngg ttoo iinnssttaallllaattiioonn iinnssttrruuccttiioonnss aanndd
wwiirriinngg ddiiaaggrraammss tthhaatt aarree pprroovviiddeedd wwiitthh tthhee eevvaappoorraattoorr ccooiill..
Field Wiring
FIELD WIRING DIAGRAM FOR S9V2-VS WITH ONE / TWO STAGE AC OR HEAT PUMP
NOTES:
1) HP = Wiring used for Heat Pump System.
2)
CS
=
wiring
used
for
Conden
sate Switch (2 Op!ons).
3)
Y1 and/or
Y2
must
be
connected from the thermostat to
the IFC for proper airflow.
4) Remove Y1-O jumper for HP systems. O terminal must be
connected as shown for gas hea!ng opera!on during
defrost.
5) If the thermostat does not have a W2, or there are not
enough conductors, jumper W1 to W2 at the IFC.
6) A/TCONT824 thermostats do not require the use of X2.
7) For PWM (BK) enabled thermostats, cut the BK jumper on
the IFC and connect wiring.
W2
W1
R
G
B
Y2
Y1
O
W2
W1
R
G
B
Y2
Y1
HP
HP
HP
X2
R
B
Y1
O
Thermostat
Furnace
(IFC)
Outdoor Unit (OD)
(No Transformer)
HP O
CS2
CS1
Y2
BK BK
Red
Blue
Black
Green
A/TFD Field Wiring
Using EAC Terminals
EAC
R
B
Replace the factory installed 35va transformer with the 50va transformer
supplied with the air cleaner. Connect to EAC terminals on the IFC per
the wiring diagram.
FIELD WIRING DIAGRAM FOR S9V2-VS WITH SINGLE STAGE AC OR HEAT PUMP WITH 2 STAGE AIRFLOW
NOTES:
1) HP = Wiring used for Heat Pump System.
2) CS = wiring used for Condensate Switch (2 Opons).
3) Y1 and Y2 must be connected from the thermostat to the
IFC for proper airflow.
4) Thermostat must be setup for 2 stage OD.
5) IFC Must be setup for 2 stage OD using the Menu/Opon
Buons.
6) Remove Y1-O jumper for HP systems. O terminal must be
connected as shown for gas heang operaon during
defrost.
7) If the thermostat does not have a W2, or there are not
enough conductors, jumper W1 to W2 at the IFC.
8) A/TCONT824 thermostats do not require the use of X2.
9) For PWM (BK) enabled thermostats, cut the BK jumper on
the IFC and connect wiring.
W2
W1
R
G
B
Y2
Y1
O
W2
W1
R
G
B
Y2
Y1
HP
HP
HP
X2
R
B
Y1
O
Thermostat
Furnace
(IFC)
Outdoor Unit (OD)
(No Transformer)
HP O
CS2
CS1
BK BK
Red
Blue
Black
Green
A/TFD Field Wiring
Using EAC Terminals
EAC
R
B
Replace the factory installed 35va transformer with the 50va transformer
supplied with the air cleaner. Connect to EAC terminals on the IFC per
the wiring diagram.