26
CG-SVX039C-GB
CXAF CXAF CXAF CXAF CXAF CXAF
130 140 150 165 180 190
SE SE SE SE SE SE
Twin pump - Standard head pressure option
Max available Head Pressure (kPa) 157 141 143 182 163 154
Motor Power (kW) 7.5 7.5 7.5 11 11 11
Rated Amps (A) 14.4 14.4 14.4 20.8 20.8 20.8
Twin pump - High head pressure option
Max available Head Pressure (kPa) 232 252 258 249 230 221
Motor Power (kW) 11 15 15 15 15 15
Rated Amps (A) 20.8 28 28 28 28 28
Expansion Tank Volume (l) 50 50 50 50 50 50
Max User water loop Volume for factory
mounted expansion tank (1)
(l) 1750 1750 1750 1750 1750 1750
Optional water Buffer tank volume (l) 607 777 777 777 777 777
Antifreeze Heater without pump package
and without buffer tank
(W) 520 640 640 640 640 640
Antifreeze Heater with pump package and
without buffer tank (Single Water Pump
digit 24=2 or 4 / Dual Water Pump digit
24=1 or 3)
(W) 1060 / 1220 1340 / 1400 1340 / 1400 1340 / 1400 1340 / 1400 1340 / 1400
Antifreeze Heater with pump package
and with buffer tank (Single Water Pump
digit 24=2 or 4 / Dual Water Pump digit
24=1 or 3)
(W) 2040 / 2100 2790/ 2850 2790/ 2850 2790/ 2850 2790/ 2850 2790/ 2850
Condenser
Type Fin-tube heat exchanger
Quantity of coil # 8 10 10 10 12 12
Face area per circuit (m²) 9.29 11.61 11.61 11.61 13.93 13.93
Condenser Fan
Quantity # 8 10 10 10 12 12
Diameter (mm) 800 800 800 800 800 800
Digit 56=1 #
Fan / motor Type # # # # # # #
Airow per fan m3/h 17976 18047 18010 17966 18018 17980
Max Power Input per Motor Kw 1.4 1.4 1.4 1.4 1.4 1.4
Max Amps per Motor A 2.8 2.8 2.8 2.8 2.8 2.8
Motor RPM (rpm) 900 900 900 900 900 900
Digit 56=2 #
Fan / motor Type # # # # # # #
Airow per fan m3/h 18983 17562 18378 18974 17959 18987
Max Power Input per Motor Kw 1.55 1.55 1.55 1.55 1.55 1.55
Max Amps per Motor A 2.5 2.5 2.5 2.5 2.5 2.5
Motor RPM (rpm) 950 880 920 950 900 950
Digit 56 =3 #
Fan / motor Type # # # # # # #
Airow per fan m3/h 19201 17868 18533 19191 18307 19204
Max Power Input per Motor Kw 1.82 1.82 1.82 1.82 1.82 1.82
Max Amps per Motor A 2.9 2.9 2.9 2.9 2.9 2.9
Motor RPM (rpm) 880 820 850 880 840 880
Dimensions
Unit Length (mm) 4520 5645 5645 5645 6770 6770
Unit Width (mm) 2200 2200 2200 2200 2200 2200
Std Unit Height (mm) 2526 2526 2526 2526 2526 2526
Pump Package Option - (Additional length
conguration)
(mm) 562 562 562 562 562 562
Weights (6)
Shipping Weight (6) (kg) 3141 3768 3944 3984 4438 4507
Option Additional shipping weight (6) #
Single pump - Standard head pressure (kg) 264 287 287 351 401 401
Single pump - High head pressure (kg) 301 363 363 363 413 413
Twin pump - Standard head pressure (kg) 363 386 386 495 545 545
Twin pump - High head pressure (kg) 425 521 521 521 571 571
XLN option (kg) 114 145 145 145 145 145
Pump VFD option (kg) 70 70 70 70 70 70
Water Buffer tank option (kg) 286 379 379 379 379 379
Table 6 – General data CXAF 130 -190 Standard Efficiency (continued)