CG-SVX039C-GB
7
Unit Model Number Description
Digit 32 – Electrical Panel Protection
X = Enclosure with deadfront protection
1 = Enclosure with IP 20 internal protection
Digit 33 – Master Slave
X = Without
A = With
Digit 34 – Unit User Interface
L = Standard, Local UI supplied (TD7)
Digit 35 – Energy Meter
X = No energy meter
M = Energy meter installed
Digit 36 – Mini Chiller Plant Control
X = No Mini PC
Digit 37 – Variable Primary Flow
X = Constant speed pump (No VFD)
A = Pump flow controlled by 3 ways valve
F = Constant Speed Pump -VFD Adjustment
P = Variable Speed Pump - Constant delta P
T = Variable Speed Pump - Constant delta T
Digit 38 – Refrigeration Leak Detection
X = Not installed
V = Installed
Digit 39 – Web Server
X = Not installed
Digit 40 – Power Socket
X = None
P = Included (230V - 100W)
Digit 41 – Factory Tests
X = None
B = Visual inspection with Customer
C = Performance Test with Customer: 1 Point
D = Performance Test with Customer: 2 Points
E = Performance Test without Customer: 1 Point
S = Special
Digit 42 – Installation Accessory
X = None
1 = Neoprene Isolators
4 = Neoprene Pads
Digit 43 – Literature Language
B = Bulgarian
C = Spanish
D = German
E = English
F = French
H = Dutch
I = Italian
K = Finnish
L = Danish
M = Swedish
N = Norwegian
P = Polish
R = Russian
T = Czech
U = Greek
V = Portuguese
Z = Slovenian
2 = Romanian
3 = Serbian
4 = Slovak
5 = Croatian
6 = Hungarian
8 = Turkish
Digit 44 – Shipping Package
X = Standard protection
A = Containerization package
Digit 45 – Refrigerant
X = None
A = R410A Factory full Refrigerant charge
8 = R410A Factory Refrigerant Pre-Charge
Digit 46 – Isolator Valve Per Manifold Compressor
X = None
A = With
Digit 47 – Power Factor Correction Capacitors
A = With
X = None
Digit 48 – Open for Future Use = X
Digit 49 – Freeze Protection (Factory Installed)
X = None
2 = With freeze protection
Digit 50 – Buffer Tank
X = No Tank
1 = With Tank
2 = With Buffer Tank-Compatible with Auxiliary Electric
Heater
Digit 51 – Water Strainer
X = No strainer
A = Factory installed strainer
Digit 52 – Louvered Panels
X = None
A = Architectural louvered panels
Digit 53 – Open for Future Use = X
Digit 54 – Starter Type
A = Across the line starter/Direct On Line
B = Soft starter
Digit 55 – Annunciation Relay
X = None
A = With
Digit 56 – Fan Type
1 = AC fan
2 = EC fan
3 = EC HESP
Digit 57 – Night Noise Setback (NNSB)
X = Without
1 = With NNSB
Digit 58 – Design Special
X = Standard
S = Special requirement

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane SINTESIS ADVANTAGE CXAF Series and is the answer not in the manual?

Trane SINTESIS ADVANTAGE CXAF Series Specifications

General IconGeneral
BrandTrane
ModelSINTESIS ADVANTAGE CXAF Series
CategoryChiller
LanguageEnglish

Related product manuals