EasyManua.ls Logo

Trane Sintesis Balance CMAF - Page 13

Trane Sintesis Balance CMAF
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11UNT-PRC002-GB
Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78
CG-SVX051A-GB
13
Unit size 080 090 100
Dimensions and weight (basic model only)
Length mm 4520 4520 4520
Width mm 2200 2200 2200
Height mm 2530 2530 2530
Pump Package Option - (Additional length) mm 555 555 555
Weights
Operating Weight kg 2459 2591 2691
Additional Shipping Weight kg 12 12 12
Additional Weight of options
Chilled water pump
Single pump - Standard head pressure kg 254 254 254
Single pump - High head pressure kg 301 301 301
Twin pump - Standard head pressure kg 343 343 343
Twin pump - High head pressure kg 425 425 425
Hot water pump
Single pump - Standard head pressure kg 145 145 145
Single pump - High head pressure kg 187 187 187
Double pump - Standard head pressure kg 225 225 225
Double pump - High head pressure kg 307 307 307
Extra Low Noise (XLN) Option kg 115 115 115
Optional Pump VFD kg 85 85 85
Optional Chilled Water Buffer tank kg 253 253 253
Oil and Refrigerant Charge (R410A)
Total Refrigerant charge Circuit 1/2 (6) kg 35/36 36/36 36/37
Refrigerant Charge per cooling kW (6) kg/kW 0.26 0.24 0.22
POE Oil Type OIL058E / OIL057E
Oil charge Circuit 1 / 2 (6) l 14.8 / 14.8 14.8 / 14.8 14.9 / 14.9
(1) Indicative performance at chilled water exchanger water temperature : 12˚C / 7˚C and air temperature 35˚C for cooling only mode & hot water
exchanger temperature: 40˚C / 45˚C and air temperature 7˚C (6˚C) for heating only mode for- detailed performances, on a given unit, consult Order
Write Up.
(2) Under 400V/3/50Hz.
(3) Rated Condition without Pump Package.
(4) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
(5) Hot water exchanger temperature 40˚C / 50 ˚C and air temperature 7˚C (6˚C) for heating only mode.
(6) Refrigerant and oil charges are indicative. Refer to unit nameplate for real charges.
Table 1 - General data CMAF 080-100 Standard Short Efficiency (Continued)
General Data