21 48626782 rev 2
Contents
4.1. Error Messages and Actions
Error
Code
Error Description
Error Displayed on
Remote
Unit Response
Action to be
taken by user
0x01 EEPROM ERROR
ERROR 01 EEPROM
communication error
contact service technician
Unit stops
working
Contact service
technician
0x02
COMPRESSOR FAILURE
ERROR OR Refrigerant
Leakage Error
Error 02 Compressor
failure or refrigerant
leakage contact service
technician
0x03 FILTER CHOKE ERROR
Error 03 Filter choke error
-Clean the lter
Unit operates as
per user settings
Clean lters
0x04
INDOOR TEMP SENSOR
ERROR (Room)
Error 04 Room temp
sensor failure contact
service technician
Cool mode or
Dry mode: Unit
operate with
Compressor OFF
Fan mode:
Operates as per
user setting
Contact service
technician
0x05
OUTDOOR TEMP SENSOR
ERROR
Error 05 outdoor temp
sensor failure contact
service technician
Operates indoor
unit and outdoor
unit as per user
setting. If TRANE
mode is activated
unit should
operate at set
point 24 °C.
0x06
INDOOR COIL SENSOR
ERROR
Error 06 Indoor temp
sensor failure contact
service technician
Cool mode or
Dry mode: Unit
operate with
Compressor OFF
Fan mode:
Operates as per
user setting
Contact service
technician
0x08 COMMUNICATION ERROR
Error 08 Communication
error contact service
technician
Stop indoor unit
and outdoor unit
0x09 BATTERY LOW ERROR
Error 09 Low battery
please change the battery
Operates indoor
unit and outdoor
unit as per user
setting.
Change battery
0x0A INPUT POWER ERROR
ERROR 10 IDU ERROR -
INPUT POWER PROBLEM
Unit stops
working
Check the power
cord / Contact
service technician
0x0B FAN FAILURE ERROR
ERROR 11 IDU ERROR -
FAN FAILURE
Contact service
technician

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane SPLIT AC and is the answer not in the manual?

Trane SPLIT AC Specifications

General IconGeneral
TypeSplit AC
Cooling CapacityVaries by model (e.g., 1.5 Ton, 2 Ton, etc.)
Energy Efficiency Ratio (EER)Varies by model (typically ranges from 8.5 to 12.5)
Power Supply220-240V, 50Hz
RefrigerantR-410A
Noise Level (Indoor Unit)Approximately 19-45 dB(A)
Noise Level (Outdoor Unit)Varies by model (e.g., 50-60 dB(A))
Air Flow (Indoor Unit)Varies by model
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model