EasyManua.ls Logo

Trane XR203 - Stage Heat Pump with GAT2, GAM2, TEM3, TEM4; Or 2 Stage Heat Pump with GAM5 A or TAM4 or GAF2-36 M

Trane XR203
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and User Guide
12 Pub. No. 18HD50D1-1A-EN 12/2018 Part No. 37-7768003
NOTES:
1) Wire third party condensate overow
switches between Y of the thermostat
and Y1 of the airow control board
2) X2 is required to energize aux heat
during defrost
Heat Pump with GAT2, GAM2, TEM3, TEM4
Indoor Unit Outdoor UnitThermostat
Rc
Rh
O/B
Y
G
W/E
C
L
Y2
W2
R
O
G
W
B
B
X2
Y/Y1
R
W2
W2
NOTES:
1) Wire third party conden-
sate overow switches
between Y of the thermo-
stat and Y1 of the airow
control board
2) X2 is required to energize
aux heat during defrost
1 or 2 Stage Heat Pump with GAM5A OR TAM4 OR GAF2-36M
Indoor Unit Outdoor UnitThermostat
Rc
Rh
O/B
Y
G
W/E
C
L
Y2
W2
R
O
G
W1
B
B
X2
Y/Y1
R
W2
W3
Y2
Y2
Y0
O
Y1

Related product manuals