Safety Label 43
© Travis Industries 4090812 100-01232_001
Safety Label
The safety (listing) label is attached to the operating tag (chained to the heater near the gas control
valve). A copy is shown below
Tested &
Listed By
Certified for USA and Canada
Vented Gas Fireplace Heater
Report No. 028-S-73b-5
DVS GSR Insert
Report No. 028-S-73c-5
31 DVI Insert
Tested to: ANSI Z21.88-2009/CSA 2.33-2009 “Vented Gas Fireplace Heater”, CGA 2.17-M91, UL 307b-1995 “Gas Burning Heating Appliances for
Manufactured Homes”, and CSA P.4.1-09 Testing method for measuring annual fireplace efficiency.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas
and Propane Installation Codes, CSA B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing, in Canada or with the Manufactured Home
Constructions and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA
501A, Manufactured Home Installation Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory
conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home (USA only) where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases,
unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions. Use only approved
coaxial direct vent system to vent this appliance to the exterior. See owner’s manual for approved brands of venting.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information
manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically approved with this appliance may result
in property damage or personal injury.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
CAUTION:
Hot while in operation. Do Not Touch. Severe burns may result. Keep children, clothing, furniture,
gasoline and other liquids having flammable vapors away. Do not operate this appliance with glass removed,
cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
Minimum Clearances to Combustibles
Side of Insert to Adjacent Wall
Hearth Extension in Front
Hearth Extension to Sides of Insert
4.5” (114mm)
0” (0mm)
0” (0mm)
Base of Insert to Mantel*
Base of Insert to Top Facing*
Flue Vent
34” to 35” (863 to 889mm)
35” (889mm)
See Owner’s Manual
*See the Owner’s Manual for complete details and additional installation options.
FAN TYPE VENTED CIRCULATOR
Blower Electrical Rating: 115V., 1.5 Amps, 60 Hz, 150 Watts
31 DVI Optional Blower: #99000167
Minimum Inlet Pressure (inches W.C.)
Maximum Inlet Pressure (inches W.C.)
Manifold Pressure on “HI” (inches W.C.)
L.P.
11”
13”
11”
N.G.
5.5”
7”
3.5”
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
Orifice Size - Front (DMS)
Orifice Size - Rear (DMS)
L.P.
31,000
12,600
#56
#56
N.G.
31,000
10,700
#50
#47
This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See owner’s manual for information on making these changes.
2011
2012
2010
Feb.
Mar.
Jan.
May
Jun.
Apr.
Aug.
Sep.
Jul.
Nov.
Dec.
Oct.
MANUFACTURE DATE:
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Manufactured by:
www.travisproducts.com
0837 IGN