EasyManua.ls Logo

Trilithic Seeker D - Seeker MCA III Error Codes (Optional)

Trilithic Seeker D
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Seeker D User’s Guide
Document Num., Rev. 4 May 2018Page 62
Seeker MCA III Error Codes (Optional)
The codes shown below are displayed on the Seeker D display
screen as “CE##” to indicate an error with the optional Seeker
MCA III
“CE##”
Code
Error Description Solution
3 Factory Calibration is not valid
Return the device to the factory for
repair.
4 User Parameters are not valid
Use Seeker Setup to recongure the
device.
7 Invalid Flash ID detected
Cycle power on the unit, if the error
persists return the device to the factory
for repair.
8 Flash memory is Full
Use any of the means available to
either erase the data, synchronize to
the meter, or move the data to a valid
LAW connection.
9 Flash memory write failed
If the error persists, return the device
to the factory for repair.
10 Wi-Fi SPI interface failed
If the error persists, return the device
to the factory for repair.
11 Wi-Fi module boot failure
If the error persists, return the device
to the factory for repair.

Table of Contents

Related product manuals