Troubleshooting/Maintenance
Condition LCD Display
LED
Status
Audible
Alarm Explanation Solution
No AC
Output
N/A N/A No There is no
AC output for
most critical
conditions. The
ground fault
circuit will also
interrupt AC
power when too
much current
flows on the
ground connector
of the GFCI.
If there is no
AC output from
the hardwire
connection,
verify if the
vehicle-equipped
GFCI outlets or
circuit breaker is
not tripped and
that all wires of
connections are
properly secured
to terminal inputs
at all connection
points.
Follow
instructions of
above event
conditions to
restore output
power. If GFCI is
tripped, remove
load and push
in the reset
switch of the
GFCI receptacle
to restore AC
output. Full GFCI
functionality
must be verified
for proper
operation after
each electrical
fault by using an
approved GFCI
tester. Once
verified, remove
tester and push
in the reset
switch of the
GFCI to restore
AC output.
Reconnect your
AC load.
Output
Short-
Circuit
Green: On
Red: On
Yes A connected
device has a
short circuit at
output which will
cause the unit
to shut down
immediately.
Remove the
connected loads
and check for
issues. Check
all connections.
Restart the
inverter.