Appendix G. V6 COM PCB Reset
In the unlikely event that communication to a SeaKing becomes impossible, units fitted with
a V6 COM PCB can be reset to a pre-determined standard using the magnetic reset function
The default values that will be applied to the SeaKing unit for the magnetic reset are as
follows:
Item changed Default value Item changed Default value
Main Port Comms RS232 Aux Port Comms RS232
Main Port Baud (Hi/Lo) 115200 / 9600 Aux Port Baud (Hi/Lo) 9600 / 9600
Main Port Parity (Hi/Lo) None Aux Port Parity (Hi/Lo) None
Main Port Data-bits (Hi/
Lo)
8 Aux Port Data-bits (Hi/
Lo)
8
ARCNET Baud (Hi/Lo) 156 / 78 Half-Duplex False
ARCNET Sens (Hi/Lo) Neutral Aux. Comms rate 1000ms
ARCNET Timeout 11 [Normal] (ET3) Disable AutoComms True
COMV6 Fitted True
Main setup changes Baud rate changes
Within the standard SeaKing accessory kit there is a strong magnet supplied specifically for
this purpose.