22
T150Z pumped thermostatic electric shower
Instructions for installers and service engineers only
INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
It is recommended that the filter is periodically
cleaned in order to maintain the performance of
the shower. It is essential that this operation is
carried out by a competent person.
Switch off the electricity and water supply
to the shower.
The inlet filter is situated inside the water inlet
fitting
(fig.24).
To gain access to the filter remove the cover and
right hand trim plate. Unscrew the cap on the
water inlet fitting.
Inspect the O ring for damage when the filter is
removed. Do not over tighten the filter cap on
reassembly.
When cleaning the filter,
DO NOT use a sharp
object, as it will cause damage. It is preferable to
use an old toothbrush or similar.
O ring
CLEANING THE FILTER
Fig.24