PLUMBING CONNECTIONS
Plumbing to be carried out before wiring.
DO NOT use jointing compounds on any pipe
fittings for the installation.
DO NOT use soldered fittings near the unit as
heat can transfer along the pipework and can
damage components.
Note: An additional isolating valve (complying
with Water Regulations/Bylaws)
MUST be fitted
in the mains water supply to the unit as an
independent means of isolating the water supply
should maintenance or servicing be necessary.
IMPORTANT: Before completing the
connection of the water supply to the inlet of
the unit, flush out the pipework to remove all
swarf and system debris. To do this, connect
a hose to the pipework and turn on the mains
water supply long enough to clear the debris
to waste.
Procedure
Turn off the water supply either at the mains
stop valve or the isolating stop valve.
Connect the mains water supply to the inlet of
the unit via 15mm pipe using the nut and olive
supplied
(fig.8). Make sure the filter is inserted
in the pipe before connection. This helps to
prevent ingress of debris.
Check the backplate is square on the wall and
then tighten the two retaining screws which
hold it to the wall.
Turn on the mains water supply and check for
leaks in the pipework connection to the unit.
WARNING!
The outlet of the unit acts as a vent
and must not be connected to any tap
or fitting not recommended by Triton