T30i
18
1 Unit inoperable,
no water flow.
2 Water too hot.
3 Water
temperature cycling
hot/cold at intervals.
4 Water too cool
or cold.
1.1 No mains water
supply to unit.
1.2 Unit malfunction.
2.1 Not enough water
flowing through the unit.
2.2 Blockage in supply.
2.3 Increase in ambient
water temperature.
3.1 Heater cycling on
thermal cut- out.
4.1 Too much flow.
4.2 Water pressure
below minimum stated
on rating label
4.3 Reduction
in ambient water
temperature.
4.4 Electrical
malfunction.
4.5 Interrupted power
supply.
1.1.1 Check if isolating valves are fully open.
Check if a blockage in inlet filter or in pipework.
1.2.1 Have unit checked. Ring Customer Service.
2.1.1 Increase the flow rate.
2.1.2 Blocked sprayhead - clean or replace
blocked spray rings.
2.2.1 Check if stop valves are fully open. Check
if blockage in inlet filter.
2.3.1 Increase the flow rate.
3.1.1 See 'Water too hot' causes 2.1, 2.2 and 2.3
and their appropriate action/cures. If it continues,
contact Customer Service.
4.1.1 Reduce the flow rate.
4.2.1 Is water supply mains or tank fed ?
4.2.2 If tank fed, replumb to mains water supply
or see 4.2.4.
4.2.3 If mains fed, ensure that mains stop
valve is fully open and that there are no other
restrictions in the supply while the unit is in use,
or see 4.2.4.
4.2.4 Fit a pump to give minimum pressure.
Contact Customer Service for advice.
4.3.1 Reduce the flow rate.
4.4.1 Have unit checked by suitably qualified
electrician or contact Triton Customer Service.
4.5.1 Blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit breaker. If it
fails again, consult a qualified electrician.
4.5.2 Power cut. Check other appliances and
if necessary, contact local Electricity Supply
Company.
FAULT FINDING
IMPORTANT: Switch OFF the electricity at the mains supply and remove the circuit fuse before
removing the cover from the handwash while attempting any fault finding inside the unit.
Problem/Symptom Cause Action/Cure

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triton T30i and is the answer not in the manual?

Triton T30i Specifications

General IconGeneral
Power Rating3kW
Installation TypeWall mounted
Water Connection15mm compression
Energy Efficiency ClassA
Voltage230V
Frequency50Hz
ProtectionIPX4
Water Pressure0.7 bar to 10 bar

Related product manuals