SITING OF THE UNIT
IMPORTANT: For ease of servicing, the unit
must always be mounted on the surface of
tiled walls. NEVER tile up to the unit.
Refer to fig.4 for correct siting of the handwash
unit.
Pressure relief safety device
A pressure relief device (PRD) is designed
into the handwash unit which complies with
European standards. The PRD provides a level of
appliance protection should an excessive build
up of pressure occur within the unit.
DO NOT operate the handwash with
damaged or blocked spray rings which can
cause the PRD to operate.
When commissioning, the sprayhead must be
removed from the swivel arm or hose, while at
the same time the temperature control must
be at the minimum flow position. Failure to
follow this procedure may also cause the PRD to
operate.
Make sure the handwash is positioned over a
sink or basin, because if the PRD operates, then
water will eject from the bottom of the unit.
Should this happen, turn off the electricity and
water supplies to the unit at the isolating switch
and stop valve.
Contact Customer Service for advice on
replacing the PRD.
WARNING!
The unit MUST NOT be positioned
where it will be subjected to freezing
conditions.
IMPORTANT: The unit must be mounted
on a flat surface which covers the full width
and length of the backplate. It is important
that the wall surface is flat otherwise
difficulty may be encountered when fitting
the cover and subsequent operation of the
unit may be impaired.
IMPORTANT!
This product MUST ONLY
be connected to Cold water
mains pipework.