Mode
The Model 2701-B provides three measurement modes:
♦ In continuous mode, the gauge takes a measurement and
updates the display every second. This mode is used for
typical quality control measurements.
♦ In averaging mode, the operator can take up to 30
measurements at selected locations. The gauge then
calculates the average of the measurements. This mode
enables the operator to determine the average density
over a selected area. The Store function (see page 5-13)
records the most recent results screen when in this mode.
♦ In segregation mode, the operator can take up to 30
measurements at selected locations. The gauge then
displays the high, low, and average density of the
readings. This mode enables the operator to determine
the degree of segregation in the area being measured.
The Store function (see page 5-13) records the most
recent results screen when in this mode.
Before taking a measurement, select the appropriate
measurement mode. To select a measurement mode, press
the
〈MODE〉 key. The gauge displays:
Press the numeric key that corresponds to the desired
measurement mode. The gauge enables the selected mode,
displays a brief confirmation message, and returns to the
Ready display.