TR-36RBF INSTALL GUIDE
07/28/2021 Page 15 of 48TEC_TM_151 | REV. A | EN
SITE PREPARATION
FIG. 1.
Water line connection. Fitting included, PEX not included
Plumbing Requirements
Water Supply
1/4” PEX tubing (1/4” O.D. lines and
fittings not included)
NOTE: Copper line is not recommended.
Flow Rate 0.5 gpm / 1.89 lpm
Operating Pressure 30 psi (207 kPa)—100 psi (689 kPa)
Incoming Water
Temperature
33-100°F (0.6-38°C)
WATER SUPPLY REQUIREMENTS
The unit comes with 20” (508 mm) of polyethylene
tubing with a 1/4” O.D. push connector for customer
attachment.
Before installing your unit, prepare the water supply
line. Please see plumbing requirements in the
plumbing requirements table.
• Purge the water line prior to final connection to
the unit. This removes any debris present in the
line.
• Only connect to a potable water supply!
• Do not connect to a hot water supply!
• Install the water filter before turning on the
water supply to the icemaker. See “Water Filter
Installation” (page 19).
• A copper line is not recommended for this
application.
• Check all water line fittings for leaks.
• Tape the supply line to the floor before moving
the unit into its final installation location.
• In the water connection area (see the rough
opening illustration), tape the water line to the
floor.
WATER AREA
NOTE: DIMENSIONS MAY VARY BY ± 1/8” (3.175 mm)