800gench2.fm Rev. A 800TCU User’s Guide 2-11
Installation and Operation
AUTO TIME OUTPUT (AU)
RS-232 command only. This command will place the unit in the automatic time output
mode. Time-of-year will output once per second and continue until another command is
received.
The output string format is:
<SOH>DDD:HH:MM:SSQ<CR><LF>
where
The start bit for the carriage return character <CR> begins at the one second mark,
+0 to +1 bit time. Time will continue to output once per second until the port
receives another command (Note: This output is not available in Translator mode).
ERROR BYPASS (EB)
This command is provided to return or load the number of frames of Error Bypass. The
two-character response code returned or transmitted for a particular setting will be one of
the following:
Example Read: EB<CR>
Example Response: 03<LT>
Unit has 3 frames of Error Bypass selected
Code Line Terminator
0 none
1 carriage return
2line feed
3 carriage return and line feed
Response Code Bypass
00 No Bypass
01 1 frame
02 2 frames
..
..
..
08 8 frames
09 9 frames
10 infinite bypass