800gench2.fm Rev. A 800TCU User’s Guide 2-15
Installation and Operation
REVERSE (RV)
This command is used to place the Translator in the reverse direction.
Example:
RV<CR>
START GENERATOR (SG)
This command may be used to start the Generator.
Example:
SG<CR>
STOP GENERATOR/TRANSLATOR (ST)
This command may be used to stop the Generator or Translator depending on the
operational mode.
Example:
ST<CR>
TRANSLATE CODE SELECT (TC)
This command is provided to return or load the Translate code. The response code
returned or transmitted for a particular code will be one of the following:
Example Read: TC<CR>
Example Write: TC4<CR>
The Translate Code is loaded with XR3 Time Code
TIME (TI)
The TIME command may be used to read time from the 800 TCU or to preset the
Generator major time registers. The ASCII time data is transmitted over the RS-232
interface in the format:
QDDDHHMMSSmmm<LT>
and over the IEEE-488 interface in the format:
DDDHHMMSSmmmQ<CR>
where
Q is the time quality character (hex 30 or hex 31)
DDD is day of year
Response Code Time Code
0IRIG-G
1IRIG-A
2IRIG-B
3IRIG-E
4XR3
52137