2-16 800TCU Userās Guide 800gench2.fm Rev. A
Installation and Operation
HH is hours
MM is minutes
SS is seconds
mmm is milliseconds
<LT> is the selected line terminator
In the Synchronized Generator and Translator modes, the time quality character will be an
ASCII one (hex 31) if the unit has good reference code and an ASCII zero (hex 30). In the
Generator mode the time quality character will always be an ASCII one character.
The preset time information must be transmitted in order (days, hours, minutes and
seconds) with no fields missing and followed by a carriage return.
Example Write: TI365235945000<CR>