18
2.3.3 Power-on Utilities
Power-on Utilities provides the basic functions and can be activated by below procedures:
Turn off the power > Hold the button > Open the power > Release the button depending on the the color of the LED.
MH Series: power down and hold the right side of the Select Keys to restart the printer.
Sequences of the settings:
LED Colors
Functions
Amber
Red
(5 blinks)
Amber
(5 blinks)
Green
(5 blinks)
Green /
Amber
(5 blinks)
Red /
Amber
(5 blinks)
Solid
green
1. Sensor Calibration
(Gap / black mark
sensor)
Release
2. Self-Test
(And enter dump mode)
Release
3. Factory Default
Release
4. Bline Calibration
Release
5. Gap Calibration
Release
6. READY
(Skip AUTO.BAS)
Release