- 52 -
Start Print
SIG
This determines the trigger conditions for the printer to control GPI 1 and
GPI4.
Level
mode
Error On
Pause
When this option is enabled and the printer is paused, the error signal
(GPO_2) is LOW.
Enable
Ribbon
Low Mode
When this option is enabled and the printer is Low Ribbon (GPO_1), the
printer will generate a warning.
Enable
Ribbon
Low
Output
When the Ribbon Low Mode feature is enabled, this parameter
determines if the output signal on Pin 9 (GPO_1) is HIGH or LOW.
Active
High
Backfeed
This determines the timing of pullback.
Default
Reprint
Mode
When this option is disabled, the printer reprint function (GPI_4) will be
invalid.
Disable