EasyManuals Logo

TSC PRINTRONIX ML340P User Manual

TSC PRINTRONIX ML340P
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
46
6.4 Sensor
This option is used to calibrate the selected sensor. We recommend calibrate the sensor before printing when changing the media.
Item
Description
Default
Auto Calibration
Set the media sensor type and calibrate the selected sensor automatically.
N/A
Manual Calibration
In case Auto Calibration does not work, please use “Manual” function to set the paper length and
gap/bline size to complete the calibration setting.
N/A
Threshold Detect
Set sensor sensitivity in fixed or auto.
Auto
Maximum Length
Set the maximum length for label calibration.
254 mm
Advanced
Set the minimum paper length and maximum gap/bline length for auto-calibratIon.
0 mm
Menu Sensor
Auto Calibration
Gap
Black Mark
Continuous
Preprint
Manual Calibration Standard
Gap
Black Mark
Continuous
Threshold Detect
Auto
Fixed
Maximum Length
Advanced
Min. Paper
Max. Gap/Mark

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC PRINTRONIX ML340P and is the answer not in the manual?

TSC PRINTRONIX ML340P Specifications

General IconGeneral
BrandTSC
ModelPRINTRONIX ML340P
CategoryPrinter
LanguageEnglish

Related product manuals