Size Range . | 0.3 to 25 µm |
---|---|
Channel Sizes . | 0.3 µm and 5.0 µm fixed; 0.5, 1.0, 2.0, or 2.5 µm selectable middle channel. |
Counting Efficiency . | 50% at 0.3 µm; 100% for particles > 0.45 µm (per ISO 21501-4 and JIS) |
Concentration Limits . | 2, 000, 000 particles/ft3 at 5% coincidence loss |
Zero Count Level . | <1 count / 5 minutes (per ISO 21501-4 and JIS B9921) |
Flow Rate . | 0.1 CFM (2.83 L/min) |
Calibration . | NIST traceable with TSI® calibration system |
Sampling Modes . | Manual and automatic |
Sampling Time . | 1 second to 99 minutes 59 seconds |
Sampling Frequency . | 1 to 999 cycles or continuous |
Light Source . | Long life laser diode |
Sample Probe/Tubing . | Isokinetic sampling probe |
Exhaust . | Internal HEPA filter |
Vacuum Source . | Internal pump |
External Surface . | High impact injection molded plastic |
Communication Mode . | USB serial output |
Data Storage . | 1, 500 sample records |
Status Indicators . | Low battery and service |
Display . | 3.2-in. (8.1 cm) 160 x 160 monochrome LCD |
AC Power . (power to AC adapter) | 110 to 240 VAC 50-60 Hz Universal in-line power supply with country specific plugs |
DC Power . (power to instrument) | 9 VDC @ 1.5 A |
Battery . | Rechargeable Li-Ion |
Battery Life . | Up to 4.5 hours of continuous use |
Recharge Time . | < 3 hours |
Dimensions (L x W x H) | 9.1 x 6.3 x 2.4 in. (23 x 11 x 6.2 cm) (without isokinetic inlet) |
---|---|
Weight . | 1.3 lbs (0.58 kg) with battery |
Information on how to contact TSI for technical and application assistance.
Contact details for international service centers and technical support.
Provides instructions for safe handling of the laser-based instrument.
Details advisory and identification labels attached to the instrument.
Explains the meaning of caution, warning, and hazard symbols used in the manual.
Instructions for unpacking the instrument and verifying contents.
Lists and describes optional accessories available for the instrument.
Guide on how to install the isokinetic inlet onto the instrument.
Explains how to power the instrument using battery or AC adapter.
Step-by-step instructions for installing the rechargeable battery.
Instructions for connecting and using the AC power adapter.
Guidance on quickly setting up and starting sampling with the instrument.
Explains the recommended warm-up period for accurate results.
Overview of the main menu and basic navigation of the instrument.
Details how to use the keypad for navigating menus and performing operations.
Instructions on how to initiate and stop the sampling process.
Guide to configuring instrument settings like language, time, date, and display.
Explains how to set sample modes, time, count, and units.
Information on viewing and clearing stored sample records in the buffer.
How to adjust pump speed, data logging, and location settings.
How to connect the instrument to a PC via USB for data transfer.
Steps to install the TrakPro™ Lite Secure data transfer utility.
Recommended schedule for instrument maintenance, cleaning, and calibration.
Procedure to ensure the instrument is properly assembled and free from issues.
Instructions for cleaning the external enclosure of the instrument.
Possible causes and corrective actions for low particle counts.
Troubleshooting steps for when the instrument fails to power on.
Solutions for when the instrument fails to meet zero count specifications.
Actions to take when the instrument's battery is not charging.
What to do when the low battery indicator is displayed.
Steps to resolve issues when the software cannot connect to the instrument.
Contact information for technical and application support from TSI.
Contact details for international service and technical support.
Instructions and required information for returning the instrument for service.
Information regarding CE marking, RoHS, and laser safety compliance.
Visual representation of the instrument's dimensions and key measurements.