EN
UNI 30 E 17261 - 561.228 3 - TECHNICAL DESCRIPTION
Cap. 3 - Pag. 3/5
THIS MANUAL IS PROPERTY OF - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
Useful distance (indicative)
m
200*
Useful height (indicative)
m
60
Material flow rubber pipe **
1st tract
Intermediate tracts
Terminal
mm
∅ 50 x 69**
∅ 50 x 66
∅ 40 x 53
Particle size that can be transported
mm
0 - 8
Work environment temperature
°C
0 / +35
Maximum height above sea level of the place of installation without sensitive reduction of
the power
m
1000
Guaranteed sound power level LwA
dB
110 ***
TAB.02
* maximum distance and height cannot be reached at the same time.
** only use specific pipes for this machine.
*** The operator must use Individual Protection Devices (IPD) for hearing.
3.4 INTENDED USES
The machine has been designed and built for the following use:
FIELD OF USE: construction sector.
DECLARED USE: conveying and spraying plasters.
3.5 PRODUCTS USED FOR WORKING
Cement-based common or ready-mixed mortars, special insulating mortars, refractory mortars.
Cement or anhydride- based self-levelling screeds, grouts and concretes.