UNI 30 E 17261 - 561.228 5 - INSTALLATION
Cap. 5 - Pag. 5/5
THIS MANUAL IS PROPERTY OF - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
ELECTRIC CONNECTION
Connect the machine to the site electric control board with a neoprene cable (anti-wear rubber) marked H07RN-F, with
minimum section:
4 x 4 mm. for distance up to 20 m;
4 x 6 mm. for distance up to 50 m;
4 x 10 mm. for distance up to 100 m;
The use of an electric cable with unsuitable section jeopardises the functioning of the machine.
The site electric control board must have:
• a minimum power of 15 kW,
• suitable earthing,
• 35 A fuses (type aM),
• high-sensitivity differentials (from 30 mA),
• it must always be in compliance with national Standards in force.
Do not use the same power supply cable for the machine and for the concrete mixer.
Insert the vibrating sieve plug into the corresponding socket positioned on the electric control board (FIG.16-REF.1).
Insert the power supply cable plug into the corresponding socket positioned on the electric control board (FIG.16-REF.2).