8 Operation
8.1 LED status indications – Operation
LED Indication Meaning
PWR Green Device is operational
Green flashing IO-Link communication
FLT Red Error
bar Green Display in bar
psi Green Display in psi
kPa Green Display in kPa
MPa Green Display in MPa
MISC Green Other display unit
LOC Yellow Device locked
Yellow flashing “Lock/unlock” process active
Off Device unlocked
8.2 Display indications
Display Meaning
Flashing Measured value out of analog range
OL Value outside of the measuring range, pressure more than 5% of full
scale above the limit value
UL Value outside of the measuring range, pressure more than 5% of full
scale below the limit value
SC1 Short circuit at output 1
SC2 Short circuit at output 2
SC12 Short circuit at both outputs
boot EEPROM error
Loc Device locked
uLoc Device unlocked
---- Sensor failure
AEP + 2%
AEP
ASP
ASP 2%
t
p
analog range
Fig.14: Display – Value within the set measuring range