EasyManua.ls Logo

turck PS310 Series - 2 Notes on the Product; Product Identification; Scope of Delivery; Legal Requirements

turck PS310 Series
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Notes on the Product
Legal requirements
6
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
2 Notes on the Product
2.1 Product identification
X
Special version
Special version
X Peak pressure aperture
PS 310 1V 03 LI2UPN 8 H1 1 4 1
PS 310
Measuring cell
Measuring cell
310 Ceramic measuring cell
510 Metal measuring cell
Functional principle
PS Pressure sensor
1V
Measuring range
Measuring range
Ceramic measuring cell
OV -1 … 0 bar
1V -1 … 1 bar
1 0 … 1 bar
1A 0 … 1 bar absolute
2.5V -1 … 2.5 bar
2.5 0 … 2.5 bar
2.5A 0 … 2.5 bar absolute
Metal measuring cell
10V -1 … 10 bar
10 0 … 10 bar
10A 0 … 10 bar absolute
16 V -1 … 16 bar
16A 0 … 16 bar absolute
25V -1 … 25 bar
25A 0 … 25 bar absolute
40V -1 … 40 bar
100 0 … 100 bar
250 0 … 250 bar
400 0 … 400 bar
600 0 … 600 bar
03
Mechanical version
Mechanical version
01 G1/4" female thread
02 1/4"-18NPT female thread
03 1/4"-18NPT male thread
04 G1/4" male thread
05 7/16" UNF male thread
08 G1/2" manometer
LI2UPN 8
Electrical version /
Operating voltage
8 18...30 VPC
Output function
2UPN 2 switching outputs/
IO-Link
LI2UPN Current and
switching output/
IO-Link
H1 1 4 1
Electrical connection:
connector
/
Assignment
1 Standard assignment
Number of contacts
4 4 Contacts
Alignment
1 Straight
Design
H1 Connector
M12 × 1
2.2 Scope of delivery
The scope of delivery includes:
n Pressure sensor
n Quick-Start Guide
2.3 Legal requirements
The device is subject to the following EC directives:
n 2014/30/EU (electromagnetic compatibility)
n 2011/65/EU (RoHS Directive)

Related product manuals