EasyManua.ls Logo

turck PS310 Series - Page 25

turck PS310 Series
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V01.00 | 2020/01
25
Explanation Options Function
dFH1
Switch delay of FH1 0…60 s in increments of 0.1 s (0 = delay time
not active), only available with window mode
Fno or Fnc
dFL1
Switch delay of FL1 0…60 s in increments of 0.1 s (0 = delay time
not active), only available with window mode
Fno or Fnc
dSP2
Switch delay of SP2 0…60 s in increments of 0.1 s (0 = delay time
not active).
drP2
Switch delay of rP2 0…60 s in increments of 0.1 s (0 = delay time
not active).
dFH2
Switch delay of FH2 0…60 s in increments of 0.1 s (0 = delay time
not active), only available with window mode
Fno or Fnc
dFL2
Switch delay of FL2 0…60 s in increments of 0.1 s (0 = delay time
not active), only available with window mode
Fno or Fnc
dAP
Damping of switching output (fil-
ter)
Momentary or high frequency pressure peaks
can be filtered: 0…8 s in increments of 0.01 s
(0 = filter is deactivated)
dAA
Damping of the analog output Filter for momentary or high frequency pres-
sure peaks: 0… 8s in increments of 0.01 s
(0 = filter is deactivated)
P-n
Behavior of the switching output auto
npn n switching
pnp p switching
diSr
Display rotated by 0°
180° Display rotated by 180°
diSu
Measured value display 50 50 ms update time
200 200 ms update time
600 600 ms update time
Off Display update deactivated
coLr
Display color GrEn Display is always green.
rEd Display is always red.
G1ou Display is green if ou1 is switched, otherwise
red.
r1ou Display is red if ou1 is switched, otherwise
green.
G2ou Display is green if ou2 is switched, otherwise
red.
r2ou Display is red if ou2 is switched, otherwise
green.
G-cF Display is green if the measured value is
between switching points cFL and cFH.
r-cF Display is red if the measured value is between
switching points cFL and cFH.