Installing
Mounting the sensor on ferrous shafts (Ø > 14mm)
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
V01.00 | 2023/06 | 11
5.2 Mounting the sensor on ferrous shafts (Ø > 14mm)
Fig.3: Mounting the sensor — shaft diameter greater than 14mm
Mounting kit BTS-DSU35-Z02 allows the device to be mounted on rotating shafts made from
ferrous material with a diameter greater than 14mm.
The positioning element must be centered within the sensor's detection range. The following
prerequisites must be fulfilled for this purpose:
n The shaft is flush with the mounting surface.
n The shaft features a groove as anti-rotation protection for the positioning element.
Insert a spacer plate (0.25mm) between the sensor and the mounting surface.
Screw the sensor on to the spacer plate.
Fit mounting kit BTS-DSU35-Z02 on the shaft.
Fit the positioning element on mounting kit BTS-DSU35-Z02.
Align the positioning element in the center of the sensor's detection range. The ideal dis-
tance to the upper and lower sensor edge is 0.65mm.
Attach the positioning element. The nominal distance between the sensor and position-
ing element is 1mm.