Setting
Setting via the Easy-Teach function
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
V01.00 | 2023/06 | 17
Setting the start point of the analog signal
Turn the positioning element to the desired start point (1).
Press the teach button for 3s (2).
a The status LED flashes 1× yellow (3).
Setting the end point of the analog signal
To set the end point of the analog signal, a start point must be set.
Turn the positioning element to the desired end point (1).
Press the teach button for 5s (2).
a The status LED flashes 2× yellow (3).
Set the encoder's effective direction clockwise (CW) or counterclockwise (CCW)
Hold down the teach button for 8s (2).
a The status LED flashes 3× yellow (3).
Resetting the encoder to factory settings
Hold down the teach button for 12s (2).
a The status LED flashes 4× yellow (3).
a The set start and end points are reset to factory settings and the effective direction is
reset to CW.