PowerSeries Pro Installation Guide
Aux loading and battery selection
HS3128/HS3032/
HS3248 PCB
current draw =
120 mA Alarm
current = 700 mA
UL Resi Burg
ULC Resi Burg
UL Com Burg
UL Resi Fire UL
Home Health Care
ULC Resi Fire ULC
Com Burg
UL Resi Fire
with wired CO
Detectors
UL985 6th Ed
ULC COM Fire
Monitoring
EN50131
Grade 2
EN50131
Grade 3
Standby Time
and Alarm Time
4 h + 4 min
4 h + 5 min
4 h + 15 min
24 h + 4 min
24 h + 5 min
24 h + 4 min
24 h + 4 min + 12
h CO alarm 24 h + 30 min 12 h
30 h (AC fail
transmission
required)
60 h
Enclosure
HSC3010C HSC3030CAR HSC3010C HSC3010C HSC3010CR HSC3020C HSC3020C
Power Supply
Adapter
HS65WPSNA HS65WPSNA
HS65WPSNA
HS65WPSNAS (ULC CB
Security Level 4) (Require
high voltage barrier kit)
HS65WPSNA HS65WPSNAS HS65WPS HS65WPS
Battery capacity
/max loading
4 Ah/700 mA
7 Ah/1200 mA
14 Ah/2000 mA
17 Ah/2000 mA
4 Ah/700 mA
7 Ah/1200 mA
14 Ah/2000 mA
17 Ah/2000 mA
7 Ah/250 mA
14 Ah/500 mA
17 Ah/600 mA
14 Ah/330 mA
17 Ah/400 mA
14 Ah/500 mA
17 Ah/600 mA
17 Ah/
1200 mA
17 Ah/500
mA
17 Ah/250
mA
Recharging
current setting
Low (400 mA) for
4 Ah/High (700 mA)
Low (400 mA) for
4Ah/High (700 mA)
High (700 mA) High (700 mA) High (700 mA)
Low
(400 mA)
High (700mA)
Note: For NFA2P 2 shield installations, use 18 Ah batteries and 450 mA load for 36-hour standby. For NFA2P 3 shield installations, use 18 Ah
batteries and the same loadings as for EN50131 Grade 3 in the table above.
EUROPEAN EN50131 COMPLIANCE STATEMENT
This Product (HS3032/HS3128/HS3248) meets the requirements of Grade 3, Class II equipment as per EN50131-1:2006 + A1:2009 + A2:2017
Standards. The Model HS3032, HS3128, HS3248 Control Panel has been certified by Telefication according to EN50131-1: 2006 +A1:2009+A2:2017,
EN50131-3:2009 Type B, EN50131-6:2017 Type A, EN50131-10, EN50136-2:2013 ATS SP3 (dialer), SP4 (Ethernet), DP2 (dialer and Ethernet),
DP3 (Ethernet and plug-in cellular) when installed in enclosure models HSC3020C or HSC3020CP.
Note: The Model HS3032P, HS3128P, HS3248P consisting of Control Panel board assembly HS3032, HS3128, HS3248 with HSM2HOST8
Wireless Transceiver mounted in the HSC3020CP plastic enclosure meets the requirements of Grade 2, Class II equipment as per EN50131-1:2006 +
A1:2009 + A2:2017 Standards. The model HS3032P, HS3128P, HS3248P has been certified by Telefication according to EN50131-1: 2006
+A1:2009+A2:2017, EN50131-3:2009 Type B, EN50131-6:2017 Type A, EN50131-10, EN50136-2:2013 Grade 2, Class II, ATS SP3 (dialer), SP4
(Ethernet), DP2 (dialer and Ethernet), DP3 (Ethernet and plug-in cellular) when installed in enclosure models HSC3020CP.
This product is suitable for use in systems with the following notification options:
- A - use of two remotely powered warning devices and one ATS SP3 required (internal dialer or ethernet or plug-in cellular module)
- B - use of one self-powered warning device and one ATS SP3 required (internal dialer or ethernet or plug-in cellular module)
- C - use of dual path ATS DP2 required (any combination of internal dialer and ethernet and/or cellular module)
- D - use of an ATS SP4 required (internal ethernet or plug-in cellular module with encryption enabled)
- E - use of dual path ATS DP3 required (combination of internal ethernet and plug-in cellular module with encryption enabled)
For EN50131 compliant installations, with alarm control panels HS3248, HS3128 and HS3032, only the intrusion portion of the alarm system may be
activated.
For EN50131 compliant installations, the following functions must be disabled:
- Fire Alarm
- CO Alarm
- Auxiliary (Medical) Alarm functions
- In Section 861-21, options 1 and 2 must be off.
For EN50131 compliant installations, the following zone types must not be used:
007 Delayed 24-Hour Fire 041 -– 24-Hour CO 049 24-Hour Flood
008 Standard 24-Hour Fire 045 24-Hour Heat 052 24-Hour Non-Alarm
025 Auto Verified Fire 046 24-Hour Medical 056 24-Hour High Temperature
027 Fire Supervisory 047 24-Hour Emergency 057 24 Hour Low Temperature
040 24-Hour Gas 048 24-Hour Sprinkler* 071 Door Bell
In this configuration, no non-mandatory events are generated in the Event Buffer and compliance with minimum 500 mandatory events storage (Grade
3) is ensured as per Section 8.10.1 in EN50131-3. Compliance labeling should be removed or adjusted if non-compliant configurations are selected.
- 30 -

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tyco Power Series and is the answer not in the manual?

Tyco Power Series Specifications

General IconGeneral
SeriesPower Series
CategorySecurity System
System TypeWired/Wireless Hybrid
Power SupplyAC with battery backup
CommunicationIP
Remote AccessMobile app, web portal
Alarm Typefire, medical

Related product manuals