Communicator compatibility
Communicator
Receiver/
Panel
Description
TL880LE
Receiver
l Sur-Gard System I-IP Receiver, version 1.13+
l Sur-Gard System II Receiver, version 2.10+
l Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
l Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
l Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
Panel
l HS2016, version 1.1+
l HS2032, version 1.1+
l HS2064, version 1.1+
l HS2128, version 1.1+
Note: Enter [*][8][Installer Code][900][000] at keypad to view the panel version number.
Installation requirements
Note:For equipment used at the protected premises and intended to facilitate IP communications (hubs,
routers, NIDs, Digital Subscriber Line (DSL), cable models), 24-hour back-up power is required. Where such
cannot be facilitated, a secondary (back-up) communication channel is required.
Follow these guidelines during installation.
l Before affixing the communicator to a wall, verify the LTE signal level at the installation location. On a
keypad, press and hold the 5 key for 2 seconds to view the LTE signal level. An installation location with
a sustained signal level of two or more bars is recommended.
l When using panel power for the TL880LE module, do not exceed the panel's maximum rated total output
power. Refer to the specified panel installation instructions for details. Only one module can be used per
panel.
l Do not mount the TL880LE communicator inside of the metal alarm panel enclosure.
- 7 -