TST-100 Touchscreen Terminal Installation Guide 10
Switch Description
S2-1
S2-2
Smart mode setting:
S2-1: OFF
S2-2: OFF
RM mode setting:
S2-1:OFF
S2-2 :ON
NOTE: S2-1 and S2-2 switch settings other than the Smart mode and RM mode settings are not supported.
RM Protocol Smart Protocol
S2-3 Reserved Unused
S2-4 ON: Tamper bypass
OFF: Tamper enabled
NOTE: When you change switch S2-4, you need to power
cycle the reader for the change to take effect.
ON: Tamper bypass
OFF: Tamper enabled
NOTE: When you change switch S2-4, you need to power cycle the
reader for the change to take effect.
S2-5 ON: Keypad Scramble enabled
OFF: Keypad Scramble disabled
Unused
NOTE: You need to select the Keypad Scramble check box in the
C•CURE9000 Reader editor for this functionality.
S2-6 Reserved Unused
S2-7 ON: Beep disabled on keypad
OFF:Beep enabled on keypad
NOTE: When you change switch S2-7, you need to power
cycle the reader for the change to take effect.
Unused
NOTE: You need to select the Beep On Key Press check box in the
C•CURE9000 Reader editor for this functionality.
S2-8 ON:Beep on read enabled
OFF: Beep on read disabled
NOTE: When you change switch S2-8, you need to power
cycle the reader for the change to take effect.
Unused
NOTE: You need to select the Beep on Card Read check box in the
C•CURE9000 Reader editor for this functionality.
Table 6:S2 DIP Switch descriptions
Rotary switch position Description
0 Default operation for reader in Smart mode
1, 2, 3, 4, 5, 6, 7, 8 Reader address in RMmode
9, A, B, E, F Reserved for internal Software House use
C Configuration Mode
D Factory default reset
Table 7:SW2 rotary switch description