TST-100 Touchscreen Terminal Installation Guide 14
i. Ensure that you configure clearances, credentials, and personnel information such as card number for the reader.
j. The card reader interface displays online status.
Smart Mode configuration
Configuring the TST-100 Touchscreen Terminal in Smart mode:
1. Connect and power the reader to an IP-ACM,iSTAR Ultra G2, Ultra G2 SE, or Edge G2 using RS-485 full-duplex wiring.
2. Set the reader protocol on the S2 DIP switch. For Smart mode, ensure S2-1 and S2-2 are in the OFF position.
3. Select position C on the rotary switch.
4. Press SW1 or power cycle the reader. The Configuration menu displays on the reader after the reader restarts.
5. Select Card Type Settings Configuration on the reader display.
6. Select the card types and reorder the priority.
You can enable or disable card types with check boxes.
You can reorder card type priority with the move buttons to the right.
7. Click Save.
8. On the rotary switch, set the reader address to position 0.
9. Press SW1 or power cycle the reader. When the reader restarts, the card types and priorities display on the screen for five
seconds before starting normal reader operation.
10. Configure the reader from the CCURE 9000 Administration Station:
a. Configure an iSTAR cluster.
b. Configure an iSTAR controller and connect it to the host (iSTAR Ultra, Ultra SE (in Ultra mode), or Ultra LT, Ultra G2,
Ultra G2 SE, or Edge G2 controller). If using the reader in Smart mode, the iSTAR must be connected to an IP-ACM v1,
IP-ACM v2, iSTAR Ultra G2, Ultra G2 SE, or iSTAR Edge G2.
c. If not configured with an iSTAR Ultra G2, Ultra G2 SE, or iSTAR Edge G2, configure an IP-ACM v1 or IP-ACM v2.
Ensure that the IP-ACM is connected to the controller GCM. You can find this information in the ICU or the IP-
ACMStatus page using the IP address of the board entered into the navigation bar of a browser.
d. On RS-485 tab of the IP-ACM v1 or IP-ACM v2, configure a port by selecting the corresponding check box. The iSTAR
Device Port box appears.
e. On the General tab and in the Protocol field, select Smart from the drop-down list.
NOTE
Smart mode will not be available if offline mode is enabled on the IP-ACM v1 and IP-ACM v2.
f. On the Readers tab, configure a reader by selecting the check box. The iSTARReader configuration box appears.
g. Configure the reader (inputs, input supervision resistance, outputs, keypad options, touchscreen configuration, etc.).
h. Configure a door and assign the reader you configured to the door.
i. Ensure that you configure clearances, credentials, and personnel information such as card number for the reader.
j. The card reader interface displays online status.