TST-100 Touchscreen Terminal Installation Guide 4
Specifications and requirements
Installation requirements
Ensure the site is ready:
The module installation must be performed by a certified installer and must be installed within the same protected premise
as the controlling General Control Module (GCM).
For a UL-compliant installation, the power supply must be UL Listed to UL 294 and/or UL 603, and listed to ULC 60839-11-
1, low voltage Class 2 power limited with appropriate ratings.
Feature Smart Mode Level RM Mode Level
Destructive Attack I I
Endurance IV IV
Line Security I I
Standby Power I I
Table 2:UL 294 feature levels
All interconnecting devices must be UL Listed, low voltage Class 2 power limited.
The site must be approved and all wiring must comply with UL requirements and other codes, as appropriate. Installation
shall be in accordance with the National Electric Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I.
Mount the enclosure directly to a wall or uni-strut using suitable user-supplied hardware.
The anchoring system must be capable of sustaining, a proof load four times that of the assembly. Refer to the enclosure
dimensions for information on the weight of enclosures. This weight does not include the cables.
The cables are protected by using metal or plastic conduit, or using flexible cable grip strain relief.
The module can be powered from 12V local source.
For a UL-compliant installation the power must be approved to UL-294 and/or UL-603, and ULC-60839-11-1.
CAUTION: Changes to the TST-100 Touchscreen Terminal that are not expressly approved by the party responsible for compliance
could void your authority to operate the equipment.