TST-100 Touchscreen Terminal Installation Guide 4
Specifications and requirements
Installation requirements
Ensure the site is ready:
■ The module installation must be performed by a certified installer and must be installed within the same protected premise
as the controlling General Control Module (GCM).
■ For a UL-compliant installation, the power supply must be UL Listed to UL 294 and/or UL 603, and listed to ULC 60839-11-
1, low voltage Class 2 power limited with appropriate ratings.
Feature Smart Mode Level RM Mode Level
Destructive Attack I I
Endurance IV IV
Line Security I I
Standby Power I I
Table 2:UL 294 feature levels
■ All interconnecting devices must be UL Listed, low voltage Class 2 power limited.
■ The site must be approved and all wiring must comply with UL requirements and other codes, as appropriate. Installation
shall be in accordance with the National Electric Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I.
■ Mount the enclosure directly to a wall or uni-strut using suitable user-supplied hardware.
■ The anchoring system must be capable of sustaining, a proof load four times that of the assembly. Refer to the enclosure
dimensions for information on the weight of enclosures. This weight does not include the cables.
■ The cables are protected by using metal or plastic conduit, or using flexible cable grip strain relief.
■ The module can be powered from 12V local source.
■ For a UL-compliant installation the power must be approved to UL-294 and/or UL-603, and ULC-60839-11-1.
CAUTION: Changes to the TST-100 Touchscreen Terminal that are not expressly approved by the party responsible for compliance
could void your authority to operate the equipment.