Configuration
You can configure the TST-100 Touchscreen Terminal in either: RM mode or Smart mode. The mode of the reader is dependent
on the configuration of the DIP switch. Additionally, the reader is required to be wired as full-duplex for Smart mode and half-
duplex for RM mode. Not all features are supported while using the reader in RM mode.
NOTE
If you change any of the switch settings after system start-up, you need to reset the TST-100 Touchscreen Terminal. You can do this by
power cycling the reader or pressing SW1, the RESET button, on the board.
Refer to the
C•CURE 9000 Hardware Configuration Guide
and the
C•CURE 9000 Areas and Zones Guide
for additional
configuration information.
RM Mode configuration
Configuring the TST-100 Touchscreen Terminal in RM mode:
1. Connect and power the reader to an iSTARACM, IP-ACM, iSTAR Ultra G2, Ultra G2 SE, or Edge G2 using RS-485 half-
duplex wiring.
2. Set the reader protocol on S2 DIPswitch. For RM mode, ensure S2-1 is in the OFF position and S2-2 is in the ON position.
3. Select position C on the rotary switch.
4. Press SW1 or power cycle the reader. The Configuration menu displays on the reader after the reader restarts.
5. Select Card Type Settings Configuration on the reader display.
6. Select the card types and reorder the priority.
You can enable or disable card types with check boxes.
You can reorder card type priority with the move buttons to the right.
7. Click Save.
8. On the rotary switch, set the reader address from positions 1 to 8. Each reader must have a unique address.
9. Press SW1 or power cycle the reader. When the reader restarts, the card types and priorities display on the screen for five
seconds before starting normal reader operation.
10. From the CCURE 9000 Administration Station:
a. Configure an iSTAR cluster.
b. Configure an iSTAR controller and connect it to the host. In RM mode, you can connect the reader to an iSTAR Classic,
Pro, eX, Edge, Ultra, Ultra SE, Ultra LT, Ultra G2, Ultra G2 SE, or Edge G2 controller.
c. Configure an ACM, IP-ACM v1, or IP-ACM v2. If using the iSTAR IP-ACM v1 or IP-ACM v2 for configuration, ensure
that the IP-ACM is connected to the controller GCM. You can find this information in the ICU or the IP-ACMStatus page
using the IP address of the board entered into the navigation bar of a browser.
d. On the RS-485 tab of the ACM. IP-ACM v1, or IP-ACM v2, configure a port by selecting the corresponding check box.
The iSTAR Device Port box appears.
e. On the General tab and in the Protocol field, select RM from the drop-down list.
f. On the Readers tab, configure a reader by selecting the check box. The iSTARReader configuration box appears.
g. Configure the reader with information, such as: card formats supported, inputs, outputs, and keypad options.
h. Configure a door and assign the reader you configured to the door.
TST-100 Touchscreen Terminal Installation Guide 13