EasyManua.ls Logo

Tyco TST-100 - Environmental requirements; Power and wiring requirements; Grounding requirements

Tyco TST-100
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Environmental requirements
The TST-100 Touchscreen Terminal board has a -4°F (-2C) to 140°F (60°C) ambient temperature rating.
This TST-100 Touchscreen Terminal board has a 93% (+/-2%) humidity spec rating.
This product is for indoor and outdoor use.
Power and wiring requirements
Table 4 on Page 7 shows the power and wiring requirements for the TST-100 Touchscreen Terminal.
Signal
Power
Requirement
To AWG Shield Maximum Length
RS-485 Comm for RM
mode:
Data half-duplex 2 wire
(P6)
iSTAR ACM or IP-
ACM
22/18 Yes 4000ft. (1212m)
RS-485 Comm for Smart
mode:
Data full-duplex 4 wire
(P6)
NOTE: Full duplex has not
been evaluated by
UL.
iSTAR IP-ACM 22/18 Yes 32ft. (10m)
RS-485 Power 12Vdc, 300mA 22/18 Yes Range of 600ft. to 1500ft. (182 to
457 m.) depends on AWG
1
Supervised Inputs (J7 and
J9)
22 Yes 2000 ft. (606m)
Supervised Input
2
Input 22 Yes 2000 ft. (606m)
Outputs (J6 and J8) 11.4-12 Vdc Relay board 22/18 No
1
Check wire lengths to verify that voltage drops are acceptable. Calculations are based on a single RM-4 reader with keypad and LCD (250mA). Using 22AWG, distance =
600ft. (.0165 ohms/ft.). Using 18AWG, distance = 1500ft. (.0065 ohms/ft.).
2
To comply with UL requirements, use shielded, minimum 22 AWG stranded, twisted pair cable for monitor points, DSMs, and REXs. Use Belden 9462 or equivalent.
Table 4:Power and wiring requirements
Grounding requirements
The grounding requirements are as follows:
Grounding must follow NEC codes or the applicable local code.
Ensure that the reader is properly connected to the ground reference from the wiring on the RS-485 terminal.
When disconnecting the wiring, disconnect ground wires last, to provide maximum protection to the equipment and
personnel.
Disconnect all power sources before modifying the wiring.
TST-100 Touchscreen Terminal Installation Guide 7